Double Channel Syringe Pump

Double Channel Syringe Pump
Product Detailed
Double Channel Syringe Pump 1.Compatible Syringe: Any standard syringe with 10ml,20ml(30ml) and 50ml(60ml) 2.accurately.

Double Channel Syringe Pump

Features:Compatible with Syringes of any Brand.Automatical Calibration for Syringes of any Brand .Two channel with two governer. More economy and save space.Three working modes: Rate control mode,Time control mode and Dose-Weight control mode.Automatical Detection of Syringe types and settings.Broad range in delivery rate settings. 8 Hours internal battery life  in high capacity.Three levels of alarm volume: high, medium and low.Three levels of occlusion pressure: high, medium and low.KVO function: After infusion is complete, the pump automatically switches to the smallest flow to prevent creating the thrombus. SpecificationsCompatible Syringe: Any standard syringe with 10ml,20ml(30ml) and 50ml(60ml)Accuracy: ±2% ( Any manufacturers of syringes, right after calibration )Delivery Rate Range:50ml(60ml): 0.1ml/h~1800.0ml/h (0.1ml/h step)20ml(30ml): 0.1ml/h~800.0ml/h (0.1ml/h step)10ml: 0.1ml/h~400.0ml/h (0.1ml/h step)Time Mode Range:Volume: 0.1~999.9ml (0.1ml step)TIME: 1~1999min (1min step)Body Weight Mode Range:Volume: 0.1~999.9ml(0.1ml step)DRUG MASS: 0.1~999.9mg(0.1mg step)DOSE: 0.01~99.99ug/kg/min(0.01ug/kg/min step)WEIGHT: 0.1~300kg(0.1kg the least step)Volume Limit Range: 0~1999.9ml (0.1 ml step)Total Volume Range: 0.1~1999.9ml (0.1 ml step)Rapid injection: 50ml(60ml): 1800.0ml/h, 20ml(30ml):800.0ml/h, 10ml:400.0ml/hKVO Rate: 1ml/h

Alarms:Near empty, Syringe empty, Volume complete(a volume limit has been set ), Occlusion, Syringe loose, Operation error, Low battery and other device failures.Power Supply:AC power supply: AC 100 to 240V±10%, 50/60Hz;Internal LI Battery: 11.1V, 2000mAh. Approximmately 8 hours of continuous operation on a new and fully  charged battery running at 5ml/h.Power Consumption: ≤25VASafety level: Class I, Type BFDimensions: 280mm(L)×160mm(W)×130mm(H)Net Weight: Approximately. 3.0kgOperating Conditions: Ambient temperature: 5 to 40°C Relative humidity: 20 to 90%Storage Condition: Ambient temperature: -10 to 55°C Relative humidity: 10 to 90%Accessories: AC power line, Operational manual